Skip to main content
Office LED Lighting Upgrade in Amboy, NJ β€” Amboy, NJ
Office
63% saved

Office LED Lighting Upgrade in Amboy, NJ

Amboy, NJ2026-07-233 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Office
Facility

7,100 sq ft

Fixtures

40 installed

Energy Saved

63%

Yearly Savings

$880

Duration

3 days

Challenge

This 7,100 square foot office in Amboy, New Jersey was running 40 two-by-two fluorescent troffers drawing a combined 3.0 kilowatts across a 10-hour, five-day-per-week schedule. The aging fluorescent fixtures delivered inconsistent light levels and drove up electricity costs at a rate of $0.18 per kWh. The facility owner needed a durable, cost-effective solution that would meaningfully reduce the lighting load without disrupting the occupied workspace.

Solution

VK Light Solutions replaced all 40 fluorescent troffers with DLC-listed 2x2 LED panels rated at 28 watts each, reducing the total connected load from 3.0 kilowatts down to 1.1 kilowatts. Occupancy sensors were installed throughout the office to deliver an additional 30% runtime reduction on the new LED fixtures during unoccupied periods. Together, the fixture swap and sensor controls were engineered as a single integrated retrofit to maximize verified energy savings.

Energy Savings

The retrofit eliminates 5,762 kWh of electricity consumption per year, representing a 74% reduction in lighting energy use for the facility. At the local rate of $0.18 per kWh, that reduction translates to $1,037 in annual utility savings. The project also avoids 4,897 pounds of CO2 emissions each year.

Results

The Amboy office now operates with a lighting system that consumes roughly one-quarter of the electricity the prior fluorescent troffers required, lowering the facility's annual utility costs by over a thousand dollars. LED panel technology reduces lamp-replacement frequency compared to fluorescent sources, cutting ongoing maintenance demands for the property. The addition of occupancy sensors ensures the efficiency gains extend beyond fixture wattage alone, automatically reducing runtime whenever spaces are unoccupied.

Services Performed

  • office-lighting

Project Details

Location
Amboy, NJ
Completed
2026
Facility Size
7,100 sq ft
Fixtures Installed
40 fixtures
Fixture Type
2x2 LED Panel

Energy Savings

Before (per fixture)75W
After (per fixture)28W
Energy Saved63%

Want similar results for your facility?

Get Free QuoteContact Us

Lighting Upgrade Details

2x4 Panel Upgrade

βˆ’-179% watts

Before

90W 2x4 Fluorescent Troffer

After

251W 2x4 LED Panel

2x2 Panel Upgrade

βˆ’60% watts

Before

60W 2x2 Fluorescent Troffer

After

24W 2x2 LED Panel

Quantity
20 fixtures

4ft Strip Upgrade

βˆ’64% watts

Before

90W 4ft Fluorescent Strip

After

32W 4ft LED Strip

Quantity
20 fixtures

Installed Fixtures

  • 2x4 LED Panel
  • 2x2 LED Panel
  • 4ft LED Strip
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

Installed Controls & Smart Systems

  • Occupancy Sensor
  • Motion Sensor
  • Smart Switch
  • Smart Dimmer
  • Wireless Control Module
  • Smart Hub Control
  • Smart Lighting Control System

How the Savings Math Works

Same formula we use on every commercial energy audit, shown openly.

Before

40 fixtures Γ— 75W Γ— 10h Γ— 5d Γ— 52w Γ· 1,000
= 7,800 kWh / year
Γ— $0.18/kWh
= $1,404 / year

After

40 fixtures Γ— 28W Γ— 10h Γ— 5d Γ— 52w Γ· 1,000
= 2,912 kWh / year
Γ— $0.18/kWh
= $524 / year

Annual Savings

4,888
kWh saved / year
$880
$ saved / year at $0.18/kWh
63%
per-fixture wattage reduction

Project Photos

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929)352-4032