Skip to main content
Industrial Lighting Upgrade in Meriden, CT β€” Meriden, CT
Industrial
73% saved

Industrial Lighting Upgrade in Meriden, CT

Meriden, CT2025-04-1430 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Industrial
Facility

222,457 sq ft

Fixtures

896 installed

Energy Saved

73%

Yearly Savings

$138,378

Duration

30 days

Challenge

This large industrial facility in Meriden, Connecticut operated 896 450-watt HiBay fixtures across 222,457 square feet, drawing a combined 403.2 kW during production hours. Running 10 hours a day, five days a week, the aging high-intensity lighting system represented a substantial and avoidable energy load. The facility owner sought a retrofit solution that would meaningfully reduce both consumption and operating costs without disrupting floor operations.

Solution

VK Light Solutions replaced all 896 HiBay fixtures with DLC-listed 120-watt LED HiBay units, reducing the connected lighting load from 403.2 kW to 107.5 kW. Occupancy sensors were installed throughout the facility to deliver an additional 30% runtime reduction on the new LED system, capturing savings well beyond the fixture swap alone. The combined approach β€” efficient fixtures paired with demand-based controls β€” maximized the energy reduction achievable within the existing operating schedule.

Energy Savings

The retrofit eliminated 852,634 kWh of consumption annually, representing an 81% reduction in lighting energy use at the facility's standard rate of $0.180 per kWh. That translates to $153,474 in verified annual dollar savings returned directly to the facility's operating budget. The project also avoids 724,739 pounds of CO2 emissions each year as a result of the reduced electrical demand.

Results

The Meriden facility now operates a 107.5 kW lighting system in place of its former 403.2 kW load, producing significantly better light distribution at the task level while eliminating the maintenance demands associated with legacy HiBay technology. The occupancy sensors ensure energy is consumed only when and where it is needed, extending the practical value of the new fixtures. At $153,474 in annual savings, the facility owner gains a strong, measurable return on the investment year over year.

Services Performed

  • led-retrofit

Project Details

Location
Meriden, CT
Completed
2025
Facility Size
222,457 sq ft
Fixtures Installed
896 fixtures
Fixture Type
LED HiBay

Energy Savings

Before (per fixture)450W
After (per fixture)120W
Energy Saved73%

Want similar results for your facility?

Get Free QuoteContact Us

Lighting Upgrade Details

HiBay Upgrade

βˆ’73% watts

Before

450W HiBay

After

120W LED HiBay

Quantity
896 fixtures
Controls
Sensor
Sensors
Motion Sensor
Smart System
Smart Hub Control, Mobile App Control
Color Temperature
6000K

Installed Fixtures

  • LED HiBay
  • HiBay

Installed Controls & Smart Systems

  • Motion Sensor
  • Smart Hub Control
  • Mobile App Control
  • Wireless Control Module
  • Remote Fixture Control

How the Savings Math Works

Same formula we use on every commercial energy audit, shown openly.

Before

896 fixtures Γ— 450W Γ— 10h Γ— 5d Γ— 52w Γ· 1,000
= 1,048,320 kWh / year
Γ— $0.18/kWh
= $188,698 / year

After

896 fixtures Γ— 120W Γ— 10h Γ— 5d Γ— 52w Γ· 1,000
= 279,552 kWh / year
Γ— $0.18/kWh
= $50,319 / year

Annual Savings

768,768
kWh saved / year
$138,379
$ saved / year at $0.18/kWh
73%
per-fixture wattage reduction

Note: the headline 73% / $138,378/yr figure may differ slightly from the formula above when motion-sensor runtime reduction, rebate offsets, demand charges, or HVAC heat-load savings are included in the headline number.

Project Photos

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929) 352-4032