Office LED Lighting Upgrade in Amboy, NJ
Commercial LED lighting upgrade completed by VK Light Solutions.
7,100 sq ft
40 已安装
63%
$880
3 days
挑战
This 7,100 square foot office in Amboy, New Jersey was running 40 two-by-two fluorescent troffers drawing a combined 3.0 kilowatts across a 10-hour, five-day-per-week schedule. The aging fluorescent fixtures delivered inconsistent light levels and drove up electricity costs at a rate of $0.18 per kWh. The facility owner needed a durable, cost-effective solution that would meaningfully reduce the lighting load without disrupting the occupied workspace.
解决方案
VK Light Solutions replaced all 40 fluorescent troffers with DLC-listed 2x2 LED panels rated at 28 watts each, reducing the total connected load from 3.0 kilowatts down to 1.1 kilowatts. Occupancy sensors were installed throughout the office to deliver an additional 30% runtime reduction on the new LED fixtures during unoccupied periods. Together, the fixture swap and sensor controls were engineered as a single integrated retrofit to maximize verified energy savings.
节能效果
The retrofit eliminates 5,762 kWh of electricity consumption per year, representing a 74% reduction in lighting energy use for the facility. At the local rate of $0.18 per kWh, that reduction translates to $1,037 in annual utility savings. The project also avoids 4,897 pounds of CO2 emissions each year.
成果
The Amboy office now operates with a lighting system that consumes roughly one-quarter of the electricity the prior fluorescent troffers required, lowering the facility's annual utility costs by over a thousand dollars. LED panel technology reduces lamp-replacement frequency compared to fluorescent sources, cutting ongoing maintenance demands for the property. The addition of occupancy sensors ensures the efficiency gains extend beyond fixture wattage alone, automatically reducing runtime whenever spaces are unoccupied.
已实施的服务
- office-lighting
照明升级详情
2x4 Panel 升级
功耗 −-179%改造前
90W 2x4 Fluorescent Troffer
改造后
251W 2x4 LED Panel
2x2 Panel 升级
功耗 −60%改造前
60W 2x2 Fluorescent Troffer
改造后
24W 2x2 LED Panel
- 数量
- 20 套灯具
4ft Strip 升级
功耗 −64%改造前
90W 4ft Fluorescent Strip
改造后
32W 4ft LED Strip
- 数量
- 20 套灯具
已安装灯具
- 2x4 LED Panel
- 2x2 LED Panel
- 4ft LED Strip
- 4ft Strip
- LED Panel 2x4
- LED Panel 2x2
已安装控制与智能系统
- Occupancy Sensor
- Motion Sensor
- Smart Switch
- Smart Dimmer
- Wireless Control Module
- Smart Hub Control
- Smart Lighting Control System
节能计算原理
与我们在每次商用能源审计中使用的相同公式,公开呈现。
改造前
改造后
年度节省
项目照片
更多案例研究
VK Light Solutions 完成的其他商用LED照明项目。

Office LED Lighting Upgrade in Cranford, NJ
VK Light Solutions retrofit a 67,500 sqft office in Cranford, NJ with DLC-listed LED fixtures, delivering improved light quality and reduced energy consumption across the facility.

Distribution Center Lighting Upgrade in Oakland, NJ
A 72% energy reduction — saving $66,194/year — at a 92,400 sqft distribution center in Oakland, NJ. VK Light Solutions replaced 520 HiBay fixtures with efficient LED HiBays.

Warehouse Lighting Upgrade in Paterson, NJ
A Paterson, NJ warehouse reduced lighting energy costs by 73% — saving $40,000/year — after replacing 259 outdated 450W HiBay fixtures with 120W DLC-listed LED HiBays across 76,472 sqft.
Want Similar Results at Your Facility?
Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.
Or call (929)352-4032