Skip to main content
Office LED Lighting Upgrade in Amboy, NJ — Amboy, NJ
Office
63% saved

Office LED Lighting Upgrade in Amboy, NJ

Amboy, NJ2026-07-233 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Office
设施

7,100 sq ft

灯具

40 已安装

节省能耗

63%

年度节省

$880

工期

3 days

挑战

This 7,100 square foot office in Amboy, New Jersey was running 40 two-by-two fluorescent troffers drawing a combined 3.0 kilowatts across a 10-hour, five-day-per-week schedule. The aging fluorescent fixtures delivered inconsistent light levels and drove up electricity costs at a rate of $0.18 per kWh. The facility owner needed a durable, cost-effective solution that would meaningfully reduce the lighting load without disrupting the occupied workspace.

解决方案

VK Light Solutions replaced all 40 fluorescent troffers with DLC-listed 2x2 LED panels rated at 28 watts each, reducing the total connected load from 3.0 kilowatts down to 1.1 kilowatts. Occupancy sensors were installed throughout the office to deliver an additional 30% runtime reduction on the new LED fixtures during unoccupied periods. Together, the fixture swap and sensor controls were engineered as a single integrated retrofit to maximize verified energy savings.

节能效果

The retrofit eliminates 5,762 kWh of electricity consumption per year, representing a 74% reduction in lighting energy use for the facility. At the local rate of $0.18 per kWh, that reduction translates to $1,037 in annual utility savings. The project also avoids 4,897 pounds of CO2 emissions each year.

成果

The Amboy office now operates with a lighting system that consumes roughly one-quarter of the electricity the prior fluorescent troffers required, lowering the facility's annual utility costs by over a thousand dollars. LED panel technology reduces lamp-replacement frequency compared to fluorescent sources, cutting ongoing maintenance demands for the property. The addition of occupancy sensors ensures the efficiency gains extend beyond fixture wattage alone, automatically reducing runtime whenever spaces are unoccupied.

已实施的服务

  • office-lighting

项目详情

地点
Amboy, NJ
完成时间
2026
设施面积
7,100 sq ft
已安装灯具
40 盏灯具
灯具类型
2x2 LED Panel

节能效果

改造前(每盏灯具)75W
改造后(每盏灯具)28W
节省能耗63%

想为您的设施实现同样的效果?

获取免费报价联系我们

照明升级详情

2x4 Panel 升级

功耗 −-179%

改造前

90W 2x4 Fluorescent Troffer

改造后

251W 2x4 LED Panel

2x2 Panel 升级

功耗 −60%

改造前

60W 2x2 Fluorescent Troffer

改造后

24W 2x2 LED Panel

数量
20 套灯具

4ft Strip 升级

功耗 −64%

改造前

90W 4ft Fluorescent Strip

改造后

32W 4ft LED Strip

数量
20 套灯具

已安装灯具

  • 2x4 LED Panel
  • 2x2 LED Panel
  • 4ft LED Strip
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

已安装控制与智能系统

  • Occupancy Sensor
  • Motion Sensor
  • Smart Switch
  • Smart Dimmer
  • Wireless Control Module
  • Smart Hub Control
  • Smart Lighting Control System

节能计算原理

与我们在每次商用能源审计中使用的相同公式,公开呈现。

改造前

40 盏灯具 × 75W × 10h × 5d × 52周 ÷ 1,000
= 每年 7,800 kWh
× $0.18/kWh
= 每年 $1,404

改造后

40 盏灯具 × 28W × 10h × 5d × 52周 ÷ 1,000
= 每年 2,912 kWh
× $0.18/kWh
= 每年 $524

年度节省

4,888
每年节省 kWh
$880
按 $0.18/kWh 计每年节省的美元
63%
每盏灯具的功率降幅

项目照片

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929)352-4032