挑战

This large industrial facility in Meriden, Connecticut operated 896 450-watt HiBay fixtures across 222,457 square feet, drawing a combined 403.2 kW during production hours. Running 10 hours a day, five days a week, the aging high-intensity lighting system represented a substantial and avoidable energy load. The facility owner sought a retrofit solution that would meaningfully reduce both consumption and operating costs without disrupting floor operations.

解决方案

VK Light Solutions replaced all 896 HiBay fixtures with DLC-listed 120-watt LED HiBay units, reducing the connected lighting load from 403.2 kW to 107.5 kW. Occupancy sensors were installed throughout the facility to deliver an additional 30% runtime reduction on the new LED system, capturing savings well beyond the fixture swap alone. The combined approach — efficient fixtures paired with demand-based controls — maximized the energy reduction achievable within the existing operating schedule.

节能效果

The retrofit eliminated 852,634 kWh of consumption annually, representing an 81% reduction in lighting energy use at the facility's standard rate of $0.180 per kWh. That translates to $153,474 in verified annual dollar savings returned directly to the facility's operating budget. The project also avoids 724,739 pounds of CO2 emissions each year as a result of the reduced electrical demand.

成果

The Meriden facility now operates a 107.5 kW lighting system in place of its former 403.2 kW load, producing significantly better light distribution at the task level while eliminating the maintenance demands associated with legacy HiBay technology. The occupancy sensors ensure energy is consumed only when and where it is needed, extending the practical value of the new fixtures. At $153,474 in annual savings, the facility owner gains a strong, measurable return on the investment year over year.

已实施的服务

  • led-retrofit

项目详情

地点
Meriden, CT
完成时间
2025
设施面积
222,457 sq ft
已安装灯具
896 盏灯具
灯具类型
LED HiBay

节能效果

改造前(每盏灯具)450W
改造后(每盏灯具)120W
节省能耗73%

想为您的设施实现同样的效果?

获取免费报价联系我们

照明升级详情

HiBay 升级

功耗 −73%

改造前

450W HiBay

改造后

120W LED HiBay

数量
896 套灯具
控制方式
Sensor
传感器
Motion Sensor
智能系统
Smart Hub Control, Mobile App Control
色温
6000K

已安装灯具

  • LED HiBay
  • HiBay

已安装控制与智能系统

  • Motion Sensor
  • Smart Hub Control
  • Mobile App Control
  • Wireless Control Module
  • Remote Fixture Control

节能计算原理

与我们在每次商用能源审计中使用的相同公式,公开呈现。

改造前

896 盏灯具 × 450W × 10h × 5d × 52周 ÷ 1,000
= 每年 1,048,320 kWh
× $0.18/kWh
= 每年 $188,698

改造后

896 盏灯具 × 120W × 10h × 5d × 52周 ÷ 1,000
= 每年 279,552 kWh
× $0.18/kWh
= 每年 $50,319

年度节省

768,768
每年节省 kWh
$138,379
按 $0.18/kWh 计每年节省的美元
73%
每盏灯具的功率降幅

注:当净计入运动感应器运行时间缩减、补贴抵扣、需量电费或暖通空调热负荷节省时,标题处的 73% / 每年 $138,378 数字可能与上述公式略有出入。