Skip to main content
Industrial Lighting Upgrade in Meriden, CT — Meriden, CT
Industrial
73% saved

Industrial Lighting Upgrade in Meriden, CT

Meriden, CT2025-04-1430 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Industrial
Instalações

222,457 sq ft

Luminárias

896 instaladas

Energia economizada

73%

Economia anual

$138,378

Duração

30 days

Desafio

This large industrial facility in Meriden, Connecticut operated 896 450-watt HiBay fixtures across 222,457 square feet, drawing a combined 403.2 kW during production hours. Running 10 hours a day, five days a week, the aging high-intensity lighting system represented a substantial and avoidable energy load. The facility owner sought a retrofit solution that would meaningfully reduce both consumption and operating costs without disrupting floor operations.

Solução

VK Light Solutions replaced all 896 HiBay fixtures with DLC-listed 120-watt LED HiBay units, reducing the connected lighting load from 403.2 kW to 107.5 kW. Occupancy sensors were installed throughout the facility to deliver an additional 30% runtime reduction on the new LED system, capturing savings well beyond the fixture swap alone. The combined approach — efficient fixtures paired with demand-based controls — maximized the energy reduction achievable within the existing operating schedule.

Economia de energia

The retrofit eliminated 852,634 kWh of consumption annually, representing an 81% reduction in lighting energy use at the facility's standard rate of $0.180 per kWh. That translates to $153,474 in verified annual dollar savings returned directly to the facility's operating budget. The project also avoids 724,739 pounds of CO2 emissions each year as a result of the reduced electrical demand.

Resultados

The Meriden facility now operates a 107.5 kW lighting system in place of its former 403.2 kW load, producing significantly better light distribution at the task level while eliminating the maintenance demands associated with legacy HiBay technology. The occupancy sensors ensure energy is consumed only when and where it is needed, extending the practical value of the new fixtures. At $153,474 in annual savings, the facility owner gains a strong, measurable return on the investment year over year.

Serviços realizados

  • led-retrofit

Detalhes do projeto

Localização
Meriden, CT
Concluído
2025
Tamanho das instalações
222,457 sq ft
Luminárias instaladas
896 luminárias
Tipo de luminária
LED HiBay

Economia de energia

Antes (por luminária)450W
Depois (por luminária)120W
Energia economizada73%

Quer resultados parecidos para as suas instalações?

Orçamento grátisFale conosco

Detalhes da modernização da iluminação

Atualização de HiBay

−73% watts

Antes

450W HiBay

Depois

120W LED HiBay

Quantidade
896 luminárias
Controles
Sensor
Sensores
Motion Sensor
Sistema inteligente
Smart Hub Control, Mobile App Control
Temperatura de cor
6000K

Luminárias instaladas

  • LED HiBay
  • HiBay

Controles e sistemas inteligentes instalados

  • Motion Sensor
  • Smart Hub Control
  • Mobile App Control
  • Wireless Control Module
  • Remote Fixture Control

Como funciona o cálculo da economia

A mesma fórmula que usamos em cada auditoria energética comercial, mostrada abertamente.

Antes

896 luminárias × 450W × 10h × 5d × 52sem ÷ 1.000
= 1,048,320 kWh / ano
× $0.18/kWh
= $188,698 / ano

Depois

896 luminárias × 120W × 10h × 5d × 52sem ÷ 1.000
= 279,552 kWh / ano
× $0.18/kWh
= $50,319 / ano

Economia anual

768,768
kWh economizados / ano
$138,379
$ economizados / ano a $0.18/kWh
73%
redução de potência por luminária

Observação: o número de destaque de 73% / $138,378/ano pode diferir ligeiramente da fórmula acima quando a redução de tempo de uso por sensor de movimento, as compensações de reembolso, os encargos de demanda ou a economia de carga térmica de HVAC são incluídos no número de destaque.

Fotos do projeto

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929) 352-4032