Skip to main content
Other Lighting Upgrade in Newark, NJ — Newark, NJ
Other
73% saved

Other Lighting Upgrade in Newark, NJ

Newark, NJ2026-07-30

Commercial LED lighting upgrade completed by VK Light Solutions.

Other
Obiekt

0 sq ft

Oprawy

100 zainstalowano

Zaoszczędzona energia

73%

Oszczędności roczne

$15,444

Czas trwania

Wyzwanie

The facility in Newark, New Jersey was operating 100 legacy 450-watt HiBay fixtures, drawing a combined 45.0 kW across a 10-hour-per-day, five-day-per-week schedule. That operating profile meant the aging high-intensity fixtures were consuming significant electricity year-round with no controls in place to reduce demand during low-activity periods. The combination of high per-fixture wattage and consistent daily runtime made the lighting system one of the facility's most consequential energy costs.

Rozwiązanie

VK Light Solutions replaced all 100 existing HiBay fixtures with DLC-listed LED HiBay fixtures rated at 120 watts each, reducing the total connected load from 45.0 kW to 12.0 kW. The retrofit was a direct one-for-one fixture replacement, preserving the existing layout while dramatically lowering energy draw at every luminaire position. The new LED HiBay fixtures were selected to deliver the light output required for the facility's operating environment at a fraction of the prior wattage.

Oszczędność energii

The retrofit eliminated 85,800 kWh of electricity consumption per year, representing a 73% reduction in lighting energy use. At the facility's rate of $0.180 per kWh, that reduction translates to $15,444 in annual dollar savings. The project also avoids 72,930 pounds of CO2 emissions each year as a direct result of the lower energy demand.

Rezultaty

The facility now operates with a lighting load of 12.0 kW instead of 45.0 kW, producing a measurable and recurring reduction in utility costs of $15,444 every year. The transition to LED HiBay fixtures also reduces the frequency of lamp replacements and associated maintenance labor compared to the previous high-intensity fixtures. With no rebate program available for this project, the full savings return flows directly from the energy reduction alone, making the performance of the fixture selection the sole driver of the financial outcome.

Szczegóły projektu

Lokalizacja
Newark, NJ
Ukończono
2026
Wielkość obiektu
0 sq ft
Zainstalowane oprawy
100 opraw
Typ oprawy
LED HiBay

Oszczędność energii

Przed (na oprawę)450W
Po (na oprawę)120W
Zaoszczędzona energia73%

Chcesz podobnych rezultatów dla swojego obiektu?

Bezpłatna wycenaSkontaktuj się z nami

Szczegóły modernizacji oświetlenia

Modernizacja: HiBay

−73% mocy

Przed

450W HiBay

Po

120W LED HiBay

Ilość
100 opraw

Zainstalowane oprawy

  • LED HiBay
  • HiBay

Zainstalowane sterowanie i systemy inteligentne

  • Occupancy Sensor
  • Motion Sensor

Jak działają obliczenia oszczędności

Ten sam wzór, którego używamy w każdym komercyjnym audycie energetycznym, przedstawiony otwarcie.

Przed

100 opraw × 450W × 10h × 5d × 52 tyg. ÷ 1 000
= 117,000 kWh / rok
× $0.18/kWh
= $21,060 / rok

Po

100 opraw × 120W × 10h × 5d × 52 tyg. ÷ 1 000
= 31,200 kWh / rok
× $0.18/kWh
= $5,616 / rok

Oszczędności roczne

85,800
kWh zaoszczędzone / rok
$15,444
$ zaoszczędzone / rok przy $0.18/kWh
73%
redukcja mocy na oprawę

Zdjęcia projektu

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929)352-4032