Skip to main content
Industrial Lighting Upgrade in Meriden, CT — Meriden, CT
Industrial
73% saved

Industrial Lighting Upgrade in Meriden, CT

Meriden, CT2025-04-1430 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Industrial
시설

222,457 sq ft

조명

896 설치됨

절감된 에너지

73%

연간 절감액

$138,378

기간

30 days

과제

This large industrial facility in Meriden, Connecticut operated 896 450-watt HiBay fixtures across 222,457 square feet, drawing a combined 403.2 kW during production hours. Running 10 hours a day, five days a week, the aging high-intensity lighting system represented a substantial and avoidable energy load. The facility owner sought a retrofit solution that would meaningfully reduce both consumption and operating costs without disrupting floor operations.

솔루션

VK Light Solutions replaced all 896 HiBay fixtures with DLC-listed 120-watt LED HiBay units, reducing the connected lighting load from 403.2 kW to 107.5 kW. Occupancy sensors were installed throughout the facility to deliver an additional 30% runtime reduction on the new LED system, capturing savings well beyond the fixture swap alone. The combined approach — efficient fixtures paired with demand-based controls — maximized the energy reduction achievable within the existing operating schedule.

에너지 절감

The retrofit eliminated 852,634 kWh of consumption annually, representing an 81% reduction in lighting energy use at the facility's standard rate of $0.180 per kWh. That translates to $153,474 in verified annual dollar savings returned directly to the facility's operating budget. The project also avoids 724,739 pounds of CO2 emissions each year as a result of the reduced electrical demand.

결과

The Meriden facility now operates a 107.5 kW lighting system in place of its former 403.2 kW load, producing significantly better light distribution at the task level while eliminating the maintenance demands associated with legacy HiBay technology. The occupancy sensors ensure energy is consumed only when and where it is needed, extending the practical value of the new fixtures. At $153,474 in annual savings, the facility owner gains a strong, measurable return on the investment year over year.

수행한 서비스

  • led-retrofit

프로젝트 세부 정보

위치
Meriden, CT
완료일
2025
시설 규모
222,457 sq ft
설치된 조명
조명 896개
조명 유형
LED HiBay

에너지 절감

이전 (조명당)450W
이후 (조명당)120W
절감된 에너지73%

귀사 시설에도 비슷한 결과를 원하시나요?

무료 견적 받기문의하기

조명 업그레이드 세부 정보

HiBay 업그레이드

전력 −73%

이전

450W HiBay

이후

120W LED HiBay

수량
896개 조명
제어
Sensor
센서
Motion Sensor
스마트 시스템
Smart Hub Control, Mobile App Control
색온도
6000K

설치된 조명기구

  • LED HiBay
  • HiBay

설치된 제어 및 스마트 시스템

  • Motion Sensor
  • Smart Hub Control
  • Mobile App Control
  • Wireless Control Module
  • Remote Fixture Control

절감 계산 방식

모든 상업용 에너지 진단에 사용하는 동일한 공식을 투명하게 공개합니다.

이전

896개 조명 × 450W × 10h × 5d × 52주 ÷ 1,000
= 1,048,320 kWh / 년
× $0.18/kWh
= $188,698 / 년

이후

896개 조명 × 120W × 10h × 5d × 52주 ÷ 1,000
= 279,552 kWh / 년
× $0.18/kWh
= $50,319 / 년

연간 절감액

768,768
연간 절감 kWh
$138,379
$0.18/kWh 기준 연간 절감 $
73%
조명당 와트수 절감

참고: 동작 감지 센서로 인한 가동 시간 단축, 리베이트 상쇄, 수요 요금, HVAC 열부하 절감이 대표 수치에 포함될 경우, 73% / $138,378/년의 대표 수치가 위 공식과 약간 다를 수 있습니다.

프로젝트 사진

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929) 352-4032