Skip to main content
Office LED Lighting Upgrade in Amboy, NJ — Amboy, NJ
Office
63% saved

Office LED Lighting Upgrade in Amboy, NJ

Amboy, NJ2026-07-233 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Office
Enstalasyon

7,100 sq ft

Limyè

40 enstale

Enèji ekonomize

63%

Ekonomi anyèl

$880

Dire

3 days

Defi

This 7,100 square foot office in Amboy, New Jersey was running 40 two-by-two fluorescent troffers drawing a combined 3.0 kilowatts across a 10-hour, five-day-per-week schedule. The aging fluorescent fixtures delivered inconsistent light levels and drove up electricity costs at a rate of $0.18 per kWh. The facility owner needed a durable, cost-effective solution that would meaningfully reduce the lighting load without disrupting the occupied workspace.

Solisyon

VK Light Solutions replaced all 40 fluorescent troffers with DLC-listed 2x2 LED panels rated at 28 watts each, reducing the total connected load from 3.0 kilowatts down to 1.1 kilowatts. Occupancy sensors were installed throughout the office to deliver an additional 30% runtime reduction on the new LED fixtures during unoccupied periods. Together, the fixture swap and sensor controls were engineered as a single integrated retrofit to maximize verified energy savings.

Ekonomi enèji

The retrofit eliminates 5,762 kWh of electricity consumption per year, representing a 74% reduction in lighting energy use for the facility. At the local rate of $0.18 per kWh, that reduction translates to $1,037 in annual utility savings. The project also avoids 4,897 pounds of CO2 emissions each year.

Rezilta

The Amboy office now operates with a lighting system that consumes roughly one-quarter of the electricity the prior fluorescent troffers required, lowering the facility's annual utility costs by over a thousand dollars. LED panel technology reduces lamp-replacement frequency compared to fluorescent sources, cutting ongoing maintenance demands for the property. The addition of occupancy sensors ensures the efficiency gains extend beyond fixture wattage alone, automatically reducing runtime whenever spaces are unoccupied.

Sèvis ki fèt

  • office-lighting

Detay pwojè

Kote
Amboy, NJ
Konplete
2026
Gwosè enstalasyon
7,100 sq ft
Limyè enstale
40 limyè
Kalite limyè
2x2 LED Panel

Ekonomi enèji

Anvan (pou chak limyè)75W
Apre (pou chak limyè)28W
Enèji ekonomize63%

Ou vle rezilta menm jan an pou enstalasyon ou?

Jwenn devi gratisKontakte nou

Detay modènizasyon ekleraj

Amelyorasyon 2x4 Panel

−-179% wat

Anvan

90W 2x4 Fluorescent Troffer

Apre

251W 2x4 LED Panel

Amelyorasyon 2x2 Panel

−60% wat

Anvan

60W 2x2 Fluorescent Troffer

Apre

24W 2x2 LED Panel

Kantite
20 limyè

Amelyorasyon 4ft Strip

−64% wat

Anvan

90W 4ft Fluorescent Strip

Apre

32W 4ft LED Strip

Kantite
20 limyè

Aparèy limyè enstale

  • 2x4 LED Panel
  • 2x2 LED Panel
  • 4ft LED Strip
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

Kontwòl ak sistèm entelijan enstale

  • Occupancy Sensor
  • Motion Sensor
  • Smart Switch
  • Smart Dimmer
  • Wireless Control Module
  • Smart Hub Control
  • Smart Lighting Control System

Kijan matematik ekonomi an mache

Menm fòmil nou itilize sou chak odit enèji komèsyal, montre ouvètman.

Anvan

40 limyè × 75W × 10è × 5j × 52sm ÷ 1,000
= 7,800 kWh / ane
× $0.18/kWh
= $1,404 / ane

Apre

40 limyè × 28W × 10è × 5j × 52sm ÷ 1,000
= 2,912 kWh / ane
× $0.18/kWh
= $524 / ane

Ekonomi anyèl

4,888
kWh ekonomize / ane
$880
$ ekonomize / ane a $0.18/kWh
63%
rediksyon wataj pou chak limyè

Foto pwojè

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929)352-4032