Skip to main content
Industrial Lighting Upgrade in Meriden, CT — Meriden, CT
Industrial
73% saved

Industrial Lighting Upgrade in Meriden, CT

Meriden, CT2025-04-1430 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Industrial
Enstalasyon

222,457 sq ft

Limyè

896 enstale

Enèji ekonomize

73%

Ekonomi anyèl

$138,378

Dire

30 days

Defi

This large industrial facility in Meriden, Connecticut operated 896 450-watt HiBay fixtures across 222,457 square feet, drawing a combined 403.2 kW during production hours. Running 10 hours a day, five days a week, the aging high-intensity lighting system represented a substantial and avoidable energy load. The facility owner sought a retrofit solution that would meaningfully reduce both consumption and operating costs without disrupting floor operations.

Solisyon

VK Light Solutions replaced all 896 HiBay fixtures with DLC-listed 120-watt LED HiBay units, reducing the connected lighting load from 403.2 kW to 107.5 kW. Occupancy sensors were installed throughout the facility to deliver an additional 30% runtime reduction on the new LED system, capturing savings well beyond the fixture swap alone. The combined approach — efficient fixtures paired with demand-based controls — maximized the energy reduction achievable within the existing operating schedule.

Ekonomi enèji

The retrofit eliminated 852,634 kWh of consumption annually, representing an 81% reduction in lighting energy use at the facility's standard rate of $0.180 per kWh. That translates to $153,474 in verified annual dollar savings returned directly to the facility's operating budget. The project also avoids 724,739 pounds of CO2 emissions each year as a result of the reduced electrical demand.

Rezilta

The Meriden facility now operates a 107.5 kW lighting system in place of its former 403.2 kW load, producing significantly better light distribution at the task level while eliminating the maintenance demands associated with legacy HiBay technology. The occupancy sensors ensure energy is consumed only when and where it is needed, extending the practical value of the new fixtures. At $153,474 in annual savings, the facility owner gains a strong, measurable return on the investment year over year.

Sèvis ki fèt

  • led-retrofit

Detay pwojè

Kote
Meriden, CT
Konplete
2025
Gwosè enstalasyon
222,457 sq ft
Limyè enstale
896 limyè
Kalite limyè
LED HiBay

Ekonomi enèji

Anvan (pou chak limyè)450W
Apre (pou chak limyè)120W
Enèji ekonomize73%

Ou vle rezilta menm jan an pou enstalasyon ou?

Jwenn devi gratisKontakte nou

Detay modènizasyon ekleraj

Amelyorasyon HiBay

−73% wat

Anvan

450W HiBay

Apre

120W LED HiBay

Kantite
896 limyè
Kontwòl
Sensor
Detektè
Motion Sensor
Sistèm entelijan
Smart Hub Control, Mobile App Control
Tanperati koulè
6000K

Aparèy limyè enstale

  • LED HiBay
  • HiBay

Kontwòl ak sistèm entelijan enstale

  • Motion Sensor
  • Smart Hub Control
  • Mobile App Control
  • Wireless Control Module
  • Remote Fixture Control

Kijan matematik ekonomi an mache

Menm fòmil nou itilize sou chak odit enèji komèsyal, montre ouvètman.

Anvan

896 limyè × 450W × 10è × 5j × 52sm ÷ 1,000
= 1,048,320 kWh / ane
× $0.18/kWh
= $188,698 / ane

Apre

896 limyè × 120W × 10è × 5j × 52sm ÷ 1,000
= 279,552 kWh / ane
× $0.18/kWh
= $50,319 / ane

Ekonomi anyèl

768,768
kWh ekonomize / ane
$138,379
$ ekonomize / ane a $0.18/kWh
73%
rediksyon wataj pou chak limyè

Remak: chif tit 73% / $138,378/ane a ka diferan yon ti kras de fòmil ki anwo a lè rediksyon tan fonksyònman detektè mouvman, konpansasyon ranbousman, frè demand, oswa ekonomi chaj chalè HVAC enkli nan chif tit la.

Foto pwojè

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929) 352-4032