63% saved

Office LED Lighting Upgrade in Amboy, NJ

Amboy, NJ2026-07-233 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Office
Installation

7,100 sq ft

Luminaires

40 installés

Énergie économisée

63%

Économies annuelles

$880

Durée

3 days

Défi

This 7,100 square foot office in Amboy, New Jersey was running 40 two-by-two fluorescent troffers drawing a combined 3.0 kilowatts across a 10-hour, five-day-per-week schedule. The aging fluorescent fixtures delivered inconsistent light levels and drove up electricity costs at a rate of $0.18 per kWh. The facility owner needed a durable, cost-effective solution that would meaningfully reduce the lighting load without disrupting the occupied workspace.

Solution

VK Light Solutions replaced all 40 fluorescent troffers with DLC-listed 2x2 LED panels rated at 28 watts each, reducing the total connected load from 3.0 kilowatts down to 1.1 kilowatts. Occupancy sensors were installed throughout the office to deliver an additional 30% runtime reduction on the new LED fixtures during unoccupied periods. Together, the fixture swap and sensor controls were engineered as a single integrated retrofit to maximize verified energy savings.

Économies d'énergie

The retrofit eliminates 5,762 kWh of electricity consumption per year, representing a 74% reduction in lighting energy use for the facility. At the local rate of $0.18 per kWh, that reduction translates to $1,037 in annual utility savings. The project also avoids 4,897 pounds of CO2 emissions each year.

Résultats

The Amboy office now operates with a lighting system that consumes roughly one-quarter of the electricity the prior fluorescent troffers required, lowering the facility's annual utility costs by over a thousand dollars. LED panel technology reduces lamp-replacement frequency compared to fluorescent sources, cutting ongoing maintenance demands for the property. The addition of occupancy sensors ensures the efficiency gains extend beyond fixture wattage alone, automatically reducing runtime whenever spaces are unoccupied.

Services réalisés

  • office-lighting

Détails du projet

Emplacement
Amboy, NJ
Achevé
2026
Superficie de l'installation
7,100 sq ft
Luminaires installés
40 luminaires
Type de luminaire
2x2 LED Panel

Économies d'énergie

Avant (par luminaire)75 W
Après (par luminaire)28 W
Énergie économisée63 %

Vous voulez des résultats similaires pour votre installation ?

Devis gratuitNous contacter

Détails de la modernisation d'éclairage

Mise à niveau 2x4 Panel

−-179% watts

Avant

90W 2x4 Fluorescent Troffer

Après

251W 2x4 LED Panel

Mise à niveau 2x2 Panel

−60% watts

Avant

60W 2x2 Fluorescent Troffer

Après

24W 2x2 LED Panel

Quantité
20 luminaires

Mise à niveau 4ft Strip

−64% watts

Avant

90W 4ft Fluorescent Strip

Après

32W 4ft LED Strip

Quantité
20 luminaires

Luminaires installés

  • 2x4 LED Panel
  • 2x2 LED Panel
  • 4ft LED Strip
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

Commandes et systèmes intelligents installés

  • Occupancy Sensor
  • Motion Sensor
  • Smart Switch
  • Smart Dimmer
  • Wireless Control Module
  • Smart Hub Control
  • Smart Lighting Control System

Comment le calcul des économies fonctionne

La même formule que nous utilisons sur chaque audit énergétique commercial, présentée en toute transparence.

Avant

40 luminaires × 75 W × 10 h × 5 j × 52 sem ÷ 1 000
= 7,800 kWh / an
× $0.18/kWh
= $1,404 / an

Après

40 luminaires × 28 W × 10 h × 5 j × 52 sem ÷ 1 000
= 2,912 kWh / an
× $0.18/kWh
= $524 / an

Économies annuelles

4,888
kWh économisés / an
$880
$ économisés / an à $0.18/kWh
63%
réduction de puissance par luminaire

Photos du projet

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929)352-4032