Défi

The distribution center in Oakland, New Jersey relied on 520 legacy HiBay fixtures drawing 377 watts each — a combined load of 196 kilowatts across 92,400 square feet of active floor space. Running 10 hours a day, five days a week, those fixtures represented a substantial and largely avoidable operating cost for the facility. The aging high-bay lighting also left maintenance as an ongoing concern given the output and heat characteristics of the prior technology.

Solution

VK Light Solutions replaced all 520 existing HiBay fixtures with DLC-listed LED HiBay fixtures rated at 105 watts each, bringing the facility's total connected lighting load down from 196.0 kW to 54.6 kW. The retrofit was executed on a one-for-one basis, preserving the existing mounting positions and distribution throughout the 92,400 square foot facility. No structural or electrical infrastructure changes were required beyond the fixture swap itself.

Économies d'énergie

The retrofit eliminated 367,744 kWh of electricity consumption per year, a 72% reduction from the facility's prior lighting load. At the facility's rate of $0.18 per kWh, that reduction translates to $66,194 in annual dollar savings. The project also avoids an estimated 312,582 pounds of CO2 emissions each year.

Résultats

The Oakland distribution center now operates with a lighting system that draws less than a third of the electricity the prior HiBays required, delivering $66,194 in recurring annual utility savings. The shift to LED HiBay technology reduces lamp replacement frequency and associated maintenance labor across all 520 fixtures. The facility owner gains a predictable, lower-cost lighting infrastructure with no rebate program dependencies factored into the return on investment.

Services réalisés

  • warehouse-lighting

Détails du projet

Emplacement
Oakland, NJ
Achevé
2026
Superficie de l'installation
92,400 sq ft
Luminaires installés
520 luminaires
Type de luminaire
HiBay

Économies d'énergie

Avant (par luminaire)377 W
Après (par luminaire)105 W
Énergie économisée72 %

Vous voulez des résultats similaires pour votre installation ?

Devis gratuitNous contacter

Détails de la modernisation d'éclairage

Mise à niveau HiBay

−73% watts

Avant

450W HiBay

Après

120W HiBay

Quantité
420 luminaires

Mise à niveau Panel

−44% watts

Avant

72W Panel

Après

40W Panel

Quantité
100 luminaires

Luminaires installés

  • HiBay
  • Panel
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

Commandes et systèmes intelligents installés

  • Occupancy Sensor
  • Bluetooth Lighting Control

Comment le calcul des économies fonctionne

La même formule que nous utilisons sur chaque audit énergétique commercial, présentée en toute transparence.

Avant

520 luminaires × 377 W × 10 h × 5 j × 52 sem ÷ 1 000
= 509,704 kWh / an
× $0.18/kWh
= $91,747 / an

Après

520 luminaires × 105 W × 10 h × 5 j × 52 sem ÷ 1 000
= 141,960 kWh / an
× $0.18/kWh
= $25,553 / an

Économies annuelles

367,744
kWh économisés / an
$66,194
$ économisés / an à $0.18/kWh
72%
réduction de puissance par luminaire