Skip to main content
Distribution Center Lighting Upgrade in Oakland, NJ — Oakland, NJ
Manufacturing
72% saved

Distribution Center Lighting Upgrade in Oakland, NJ

Oakland, NJ2026-05-0228 days

Commercial LED lighting upgrade completed by VK Light Solutions.

Manufacturing
Instalación

92,400 sq ft

Luminarias

520 instaladas

Energía ahorrada

72%

Ahorro anual

$66,194

Duración

28 days

Desafío

The distribution center in Oakland, New Jersey relied on 520 legacy HiBay fixtures drawing 377 watts each — a combined load of 196 kilowatts across 92,400 square feet of active floor space. Running 10 hours a day, five days a week, those fixtures represented a substantial and largely avoidable operating cost for the facility. The aging high-bay lighting also left maintenance as an ongoing concern given the output and heat characteristics of the prior technology.

Solución

VK Light Solutions replaced all 520 existing HiBay fixtures with DLC-listed LED HiBay fixtures rated at 105 watts each, bringing the facility's total connected lighting load down from 196.0 kW to 54.6 kW. The retrofit was executed on a one-for-one basis, preserving the existing mounting positions and distribution throughout the 92,400 square foot facility. No structural or electrical infrastructure changes were required beyond the fixture swap itself.

Ahorro energético

The retrofit eliminated 367,744 kWh of electricity consumption per year, a 72% reduction from the facility's prior lighting load. At the facility's rate of $0.18 per kWh, that reduction translates to $66,194 in annual dollar savings. The project also avoids an estimated 312,582 pounds of CO2 emissions each year.

Resultados

The Oakland distribution center now operates with a lighting system that draws less than a third of the electricity the prior HiBays required, delivering $66,194 in recurring annual utility savings. The shift to LED HiBay technology reduces lamp replacement frequency and associated maintenance labor across all 520 fixtures. The facility owner gains a predictable, lower-cost lighting infrastructure with no rebate program dependencies factored into the return on investment.

Servicios realizados

  • warehouse-lighting

Detalles del proyecto

Ubicación
Oakland, NJ
Finalizado
2026
Tamaño de la instalación
92,400 sq ft
Luminarias instaladas
520 luminarias
Tipo de luminaria
HiBay

Ahorro energético

Antes (por luminaria)377W
Después (por luminaria)105W
Energía ahorrada72%

¿Quiere resultados similares para su instalación?

Obtener presupuesto gratuitoContáctenos

Detalles de la modernización de iluminación

Mejora de HiBay

−73% vatios

Antes

450W HiBay

Después

120W HiBay

Cantidad
420 luminarias

Mejora de Panel

−44% vatios

Antes

72W Panel

Después

40W Panel

Cantidad
100 luminarias

Luminarias instaladas

  • HiBay
  • Panel
  • 4ft Strip
  • LED Panel 2x4
  • LED Panel 2x2

Controles y sistemas inteligentes instalados

  • Occupancy Sensor
  • Bluetooth Lighting Control

Cómo funciona el cálculo del ahorro

La misma fórmula que usamos en cada auditoría energética comercial, mostrada abiertamente.

Antes

520 luminarias × 377W × 10h × 5d × 52sem ÷ 1,000
= 509,704 kWh / año
× $0.18/kWh
= $91,747 / año

Después

520 luminarias × 105W × 10h × 5d × 52sem ÷ 1,000
= 141,960 kWh / año
× $0.18/kWh
= $25,553 / año

Ahorro anual

367,744
kWh ahorrados / año
$66,194
$ ahorrados / año a $0.18/kWh
72%
reducción de potencia por luminaria

Fotos del proyecto

Want Similar Results at Your Facility?

Every project starts with a free on-site audit and a written photometric design. We file rebates, manage install, and verify the savings against the proposal.

Or call (929) 352-4032